Performance
Power from 0.37 to 7.5 kW
Application Limits
1. Maximum liquid temperature +35 °C
2. 200 m immersions limit
3. Starts/ hour 24 at regular intervals
4. Minimum flow rate for motor cooling 8 cm/s
5. Continuous service S1
Electric Motor
1. 2 pole electric motor, 50 Hz (n~ 2900 rpm)
2. Voltage:
* Single phase 210- 220- 230 V
* Three phase 380- 400- 415 V
3. Insulation: class F
4. Protection: IP 68
Construction and Safety Standards
1. Oil filled rewindable motors (non-toxic oil use with food)
2. Jacket: AISI 304 stainless steel
3. Shaft: AISI 304 stainless steel
4. Dimensions of the flange connection in compliance with NEMA standards.
5. Chamber: Brass
6. Complete with power cable of the following length:
a. Single phase:
0.37- 1.1 kW = 4x1.5 mm / 1.5 mt.
1.5- 2.2 kW = 4x1.5 mm / 2.5 mt.
3.0 kW = 4x2.5 mm / 3.0 mt.
b. Three phase:
0.55- 1.5 kW = 4x1.5 mm / 1.5 mt.
2.2- 4.0 kW = 4x1.5 mm / 2.5 mt.
5.5- 7.5 kW = 4x2.5 mm / 3.0 mt.
Available on request
1. Other voltages or 60 Hz. frequency